TECHNOLOGY200m Ultra Long Run LED Strip
Ultra-long-run temporary LED lighting for tunnels, infrastructure and major construction projects — designed for continuous runs of up to 200m.
Flexible LED strip luminaire engineered for tunnel, construction, infrastructure and data centre applications requiring continuous runs. SMD LED packages deliver up to 1,250 lm/m at efficacies up to 111 lm/W with 120° photometric distribution and CRI ≥80. UL94 V-0 flame-retardant PVC extrusion with integrated multi-strand copper conductors minimises resistive losses over runs up to 200m from a single power point.
Performance figures shown are per variant (100m / 150m / 200m). See the specification table for each configuration.
CONTINUOUS OPERATION & WARRANTY
Selected premium silicone and ultra-long LED strip systems are engineered for continuous-duty applications, including demanding tunnel and infrastructure projects. This range is not subject to a blanket restriction on 24-hour operation. Continuous-operation suitability, maximum connected lengths and warranty periods are product-specific and should be confirmed with LMX Lighting before ordering.
TEMPORARY CONSTRUCTION SITE LIGHTING DESIGN
Construction site illuminance is governed by BS EN 12464-2:2024, which specifies maintained average illuminance values of 20, 50, 100 and 200 lux across four construction activity categories. Emergency escape routes require 1 lux per BS EN 1838:2024. Our full construction lighting guide explains the standards, the distinction between requirement and guidance, and how to approach mounting height, spacing and maintenance factors.
READ THE CONSTRUCTION LIGHTING GUIDEDesigned for projects where long continuous lighting runs can simplify temporary lighting installation and reduce the number of supply/distribution points required compared with shorter-run lighting systems.
WHY USE LMX ULTRA LONG RUN?
Why Use LMX Ultra Long Run Lighting?
Single-run capability from a single power point.
SMD LED packages delivering high output across extended lengths.
Uniform light along the full run rather than pools of light.
Engineered for tunnel, construction and infrastructure environments.
Compared with shorter-run systems, reducing distribution points.
LMX engineering can calculate achieved illuminance for your project.
TUNNEL APPLICATION
Designed for Long Tunnel Runs
Continuous LED strip can provide longitudinal illumination along tunnel routes, offering continuous light along the access route rather than the pools of light produced by spaced point luminaires. The final number and position of lighting runs should be determined by tunnel geometry, mounting position and required illuminance.
TEMPORARY TUNNEL LIGHTING — LUX LEVELS & DESIGN GUIDEILLUSTRATIVE TUNNEL EXAMPLES
Tunnel Lighting Examples
The examples below are illustrative approximate design examples only, not guaranteed performance figures. Actual illuminance depends on tunnel geometry, mounting height and position, surface reflectance, obstructions and the selected lighting arrangement.
4m Tunnel Example — 1,200 lm/m
Illustrative example of a 4m wide tunnel using a 1,200 lm/m LMX LED strip configuration. Illustrative only — not a guaranteed performance figure.
14m Tunnel Example — 2,500 lm/m High-Output Strip
Illustrative example of a 14m wide tunnel using a 2,500 lm/m high-output LMX strip configuration — a separate high-output configuration, not the Ultra Long Run product. Illustrative only — not a guaranteed performance figure.
These examples are illustrative only and not guaranteed performance figures. The 2,500 lm/m figure relates to a separate high-output LMX strip configuration; the Ultra Long Run product remains up to 1,250 lm/m. See the full Tunnel Lighting Guide for the complete examples and design considerations.
TEMPORARY TUNNEL LIGHTING DESIGN
Tunnel construction lighting is governed by BS 6164:2019, which specifies mean lighting levels of 30 lux for walkways and tracks and 100 lux for general working areas and the tunnel face. Emergency escape routes require 1 lux per BS EN 1838:2024. Our full tunnel lighting guide explains the standards, workface shadowing, long-run LED strip benefits and electrical design considerations for extended tunnel runs.
READ THE TUNNEL LIGHTING GUIDEENGINEERED FOR DEMANDING ENVIRONMENTS
Cinematic build & light-quality showcase — precision optics, sealed housings and instant-start performance.
CERTIFICATIONS
TECHNOLOGYMaximum useful light. Maximum efficiency.
Optimised optical, thermal and electrical design for high efficacy, long service life and reduced energy consumption.
KEY ENGINEERING FEATURES
FULL SPECIFICATION TABLE
Planning a Tunnel or Long-Run Lighting Project?
Send LMX your tunnel or site dimensions, required lighting level, supply voltage and approximate run lengths. We can assess the most suitable lighting configuration and provide a project-specific lighting design.
Need a custom specification?
Our engineering team can modify any parameter to suit your project requirements.