ATEX Hazardous Area LED Strip
INTRINSICALLY SAFE ILLUMINATION
HAZARDOUS

ATEX Hazardous Area LED Strip

ATEX certified LED strip for Zone 1/21 and 2/22 hazardous area lighting — supplied as a complete explosion-proof system with optional emergency backup.

OIL & GASCHEMICALPHARMACEUTICALDUST ENVIRONMENTS

ATEX certified LED strip for Zone 1/21 and 2/22 hazardous area installations. Configurable 24V/36V/48V AC or DC input delivering up to 1,000 lm/m with CRI ≥80, housed in an IP67 / IK10 injection-moulded silicone enclosure. Available in any project-selected white CCT plus amber, green and red for safety and signalling applications.

KEY SPECIFICATIONS
LUMEN OUTPUT
Up to 1,000 lm/m
EFFICACY
Up to 83 lm/W
INPUT VOLTAGE
24V / 36V / 48V AC or DC
IP RATING
IP67
DIMENSIONS
20 mm × 10 mm
LIFETIME
50,000 hours
CCT
Project selectable
COMPLIANCE
ATEX · EN IEC 60079-0 · EN IEC 60079-18

Output and power vary according to voltage and configuration. White CCT is project selectable; coloured variants are available for safety and signalling applications.

ZONES 1, 2, 21 & 22
ATEX CERTIFIED

ATEX certified LED strip for gas and dust hazardous area installations, supplied as a complete explosion-proof lighting system with suitable power/driver enclosure and optional emergency backup.

VOLTAGE / OUTPUT CONFIGURATIONS

The ATEX LED strip is configurable across three documented voltage and output variants. Output and power vary according to voltage and configuration.

CONFIGURATION
INPUT
POWER
LIGHT OUTPUT
AC version
24V / 36V / 48V AC
12 W/m
800 lm/m
DC version
24V / 36V / 48V DC
12 W/m
1,000 lm/m
Low-power DC
24V DC
6 W/m
500 lm/m

Output and power vary according to voltage and configuration.

ATEX / EX CERTIFICATION

LED Strip Ex Markings

II 2G Ex mb op is IIC T4 Gb
II 2D Ex mb op is IIIC T135°C Db

Certification Standards

EN IEC 60079-0
EN IEC 60079-18
EN IEC 60079-28

Certification Scope

LED STRIP

ATEX documentation confirmed. The LED strip is certified for Zone 1/21 and Zone 2/22 hazardous areas per the Ex markings above.

EXPLOSION-PROOF ENCLOSURE

ATEX & IECEx documentation available for the explosion-proof power/driver enclosure. The enclosure certification is separate from the LED strip certification.

IECEx certification applies to the explosion-proof enclosure, not the LED strip itself. White CCT is a product configuration capability and does not carry a separate certificate per Kelvin value.

COMPLETE ATEX LIGHTING SYSTEM

LMX can supply the ATEX LED strip as a complete hazardous-area lighting system, including the explosion-proof power/driver enclosure, low-voltage power supply and optional emergency backup. This provides a coordinated solution from the incoming mains supply through to the hazardous-area LED strip.

01ATEX LED strip
02Explosion-proof power/driver enclosure
03Power supply/driver
04Connection system
05Optional emergency backup

EXPLOSION-PROOF POWER SUPPLY & DRIVER BOX

The mains supply is connected to the explosion-proof enclosure containing the power supply/driver, which then provides the required low voltage to the ATEX LED strip. A Mean Well driver/power supply is housed within the explosion-proof enclosure.

MAINS SUPPLY
100–240V / 277V AC
50/60Hz
EXPLOSION-PROOF
Power / Driver Box
Mean Well driver
LOW-VOLTAGE
ATEX LED Strip
24V / 36V / 48V
AC INPUT
100–240V / 277V AC, 50/60Hz
DC OUTPUT OPTIONS
12V / 24V / 36V / 48V
MAXIMUM POWER
200W

The ATEX LED strip is supplied at low voltage from the explosion-proof enclosure. Mains voltage is not connected directly to the LED strip.

OPTIONAL EMERGENCY BACKUP

Optional Emergency Lighting

The explosion-proof power/driver enclosure can be supplied with an optional battery backup system, providing 12W emergency operation for approximately 1.5 hours. Contact LMX for project-specific emergency requirements.

EMERGENCY POWER
12W
EMERGENCY DURATION
1.5 hours

APPLICATIONS

A specialist hazardous-area lighting system suitable for Zone 1/21 and Zone 2/22 applications, including locations where flammable gases, vapours or combustible dusts may be present.

Oil & gas
Petrochemical facilities
Refineries
Mines
Wastewater treatment
Tunnels
Industrial hazardous areas

ATEX HAZARDOUS AREA LIGHTING DESIGN

Choosing hazardous-area lighting depends on the classified zone, the gas or dust group and the temperature class — not on lux level alone. Our ATEX lighting guide explains zone classification, how to read the Ex markings, ATEX versus IECEx, system architecture and how to specify a compliant ATEX LED strip system for Zones 1, 2, 21 and 22.

READ THE ATEX LIGHTING GUIDE

HAZARDOUS AREA CLASSIFICATION & EX PROTECTION

Hazardous areas are classified by the likelihood of an explosive atmosphere forming and by the type of flammable substance present — gas or combustible dust. The LMX ATEX LED strip is certified for Zone 1/21 and Zone 2/22 applications. The information below explains how to read the Ex markings and what the protection ratings mean.

Zone Classification

Zone 1GAS / VAPOUR

Area in which an explosive gas atmosphere is likely to occur in normal operation occasionally.

Zone 2GAS / VAPOUR

Area in which an explosive gas atmosphere is not likely to occur in normal operation and, if it does occur, will exist only for a short period.

Zone 21COMBUSTIBLE DUST

Area in which combustible dust, as a cloud, is likely to occur in normal operation occasionally.

Zone 22COMBUSTIBLE DUST

Area in which combustible dust, as a cloud, is not likely to occur in normal operation and, if it does occur, will exist only for a short period.

How to Read the Ex Marking

The ATEX LED strip carries two Ex markings — one for gas atmospheres and one for dust atmospheres. Each marking is built from a sequence of codes that together describe the certified protection.

GAS ATMOSPHERE
II 2G Ex mb op is IIC T4 Gb
II
EQUIPMENT GROUP II
Surface industry (non-mining) equipment.
2G
CATEGORY 2G
Equipment intended for use in Zone 1 gas atmospheres (high level of protection).
Ex
EX MARKING
Indicates the equipment is designed for explosive atmospheres.
mb
TYPE OF PROTECTION
Encapsulation (moulding) — the components are embedded in a solid compound so that the explosive atmosphere cannot be ignited.
op is
TYPE OF PROTECTION
Optical radiation with intrinsic safety — the LED optical output is limited so it cannot ignite the surrounding atmosphere.
IIC
GAS GROUP
Suitable for gas groups IIA, IIB and IIC (including hydrogen, the most easily ignited common gas).
T4
TEMPERATURE CLASS
Maximum surface temperature ≤ 135°C for gas atmospheres. Ensures the surface cannot auto-ignite the surrounding gas.
Gb
EPL (GAS)
Equipment Protection Level for gas — high level of protection for Zone 1.
DUST ATMOSPHERE
II 2D Ex mb op is IIIC T135°C Db
II
EQUIPMENT GROUP II
Surface industry (non-mining) equipment.
2D
CATEGORY 2D
Equipment intended for use in Zone 21 dust atmospheres (high level of protection).
Ex
EX MARKING
Indicates the equipment is designed for explosive atmospheres.
mb
TYPE OF PROTECTION
Encapsulation (moulding) — the components are embedded in a solid compound so that the explosive atmosphere cannot be ignited.
op is
TYPE OF PROTECTION
Optical radiation with intrinsic safety — the LED optical output is limited so it cannot ignite the surrounding atmosphere.
IIIC
DUST GROUP
Suitable for dust groups IIIA, IIIB and IIIC (including conductive and very fine non-conductive dusts).
T135°C
MAXIMUM SURFACE TEMPERATURE
Maximum surface temperature 135°C for dust atmospheres. Ensures the surface cannot ignite a deposited dust layer.
Db
EPL (DUST)
Equipment Protection Level for dust — high level of protection for Zone 21.

Ingress & Impact Protection

IP67INGRESS PROTECTION

Dust-tight (6) and protected against temporary immersion up to 1m depth (7). Confirms the sealed silicone enclosure excludes solid ingress and water entry in damp or wet hazardous locations.

IK10IMPACT PROTECTION

Highest mechanical impact rating within the IK scale. Confirms the enclosure resists high-energy impacts without loss of ingress protection or structural integrity.

WHY LMX ATEX LED STRIP?

Why Use LMX ATEX Hazardous Area LED Strip?

Zones 1, 2, 21 & 22

ATEX certified for gas and combustible-dust hazardous area lighting.

Up to 1,000 lm/m

Configurable 24V/36V/48V AC or DC delivering up to 1,000 lm/m at up to 83 lm/W.

Project-selectable white CCT

Any white Kelvin value manufactured to specification; amber, green and red also available.

Explosion-proof system

Supplied as a complete system with suitable explosion-proof power/driver enclosure.

Optional emergency lighting

Emergency backup system available for hazardous-area installations.

Separate certification documentation

ATEX documentation for the strip; ATEX and IECEx documentation for the enclosure.

Project-specific lighting design

LMX engineering can configure a compliant hazardous-area lighting system.

The LED strip carries ATEX certification. The power/driver enclosure carries separate ATEX and IECEx documentation. The strip itself does not carry IECEx certification.

APPLICATIONS

Designed for Hazardous Area Lighting

01

Oil & Gas

Hazardous-area lighting for onshore and offshore oil and gas facilities.

02

Chemical & Pharmaceutical

Zone 1/2 and Zone 21/22 lighting for chemical and pharmaceutical processing environments.

03

Paint & Solvent Areas

Lighting for spray booths, solvent stores and flammable-material handling areas.

04

Grain & Dust Environments

Zone 21/22 lighting for grain handling, milling and combustible-dust environments.

PRODUCT IN MOTION
Product in motion

ENGINEERED FOR DEMANDING ENVIRONMENTS

Cinematic build & light-quality showcase — precision optics, sealed housings and instant-start performance.

CERTIFICATIONS

ATEX
EN IEC 60079-0
EN IEC 60079-18
EN IEC 60079-28
IP67
IK10

KEY ENGINEERING FEATURES

IP67 / IK10-rated injection-moulded silicone housing providing sealed ingress and impact protection across a -40°C to +80°C operating range
Configurable 24V / 36V / 48V AC or DC input with 6–12 W/m power consumption delivering up to 1,000 lm/m at up to 83 lm/W efficacy
High-efficiency SMD LED arrays with 99.9° beam angle and CRI ≥80 for uniform hazardous-area illumination
White CCT is project selectable — any white Kelvin value can be manufactured to specification; amber, green and red variants available for safety and signalling applications
L70 rated lifespan exceeding 50,000 hours for low-maintenance, energy-efficient operation
UV, solvent and saltwater resistant construction rated for damp or wet location installation, backed by a 5-year warranty
Supplied as a complete hazardous-area lighting system with explosion-proof power/driver enclosure, low-voltage power supply and optional emergency backup

FULL SPECIFICATION TABLE

PRODUCT CODE
LXEX-ST30126500
EX MARKING
II 2G Ex mb op is IIC T4 Gb; II 2D Ex mb op is IIIC T135°C Db, -40°C ≤ Ta ≤ +80°C
CERTIFICATES
ATEX, EN IEC 60079-0, EN IEC 60079-18, EN IEC 60079-28
MINIMUM BEND DIAMETER
Ø300mm — bend along the light surface only
ENVIRONMENTAL RESISTANCE
UV, solvent and saltwater resistant
SERVICE ENVIRONMENT
Damp or wet location
WARRANTY
5 years
INPUT VOLTAGE
24V / 36V / 48V AC or DC
POWER CONSUMPTION
6–12 W/m depending on configuration
LUMINOUS FLUX
Up to 1,000 lm/m
EFFICIENCY
Up to 83 lm/W
POWER FACTOR
1
BEAM ANGLE
99.9° (average beam angle 50%)
COLOUR TEMPERATURE
Project selectable – any white CCT available
COLOUR OPTIONS
White / Amber / Green / Red
CRI
≥80
NOMINAL STRIP LENGTH
2 x 15m = 30m (other lengths available)
MAXIMUM CONNECTABLE LENGTH
30m
DIMENSIONS
20 mm × 10 mm
HOUSING MATERIAL
Injection-moulded silicone (silica gel)
DIFFUSER TYPE
Integrated silicone diffuser
END CONNECTOR TYPE
Injection-moulded waterproof connector
WEIGHT
285 g/m
FLAMMABILITY (UL94)
HB
OPERATING TEMPERATURE
-40°C to +80°C
IP RATING
IP67
IK RATING
IK10
LED LIFETIME (L70)
50,000 hours
PROJECT ENQUIRY

Specifying a Hazardous Area Lighting Project?

Send us your zone classification, required lighting levels, area dimensions and supply requirements. LMX can configure a compliant ATEX LED strip system with suitable enclosure and optional emergency backup.

Need a custom specification?

Our engineering team can modify any parameter to suit your project requirements.